Search results for "Tibial fracture"
showing 10 items of 23 documents
Role of Negative Pressure Therapy as Damage Control in Soft Tissue Reconstruction for Open Tibial Fractures.
2017
AbstractThe concept of damage control orthopaedics (DCO) is a strategy that focuses on managing orthopaedic injuries in polytrauma patients who are in an unstable physiological state. The concept of DCO is an extension of damage control surgery or damage limitation surgery (DCS/DLS). Recently, it has become clear that certain patients, following extensive soft tissue trauma, could benefit from the idea of DCS. In the management of severe lower extremity trauma with exposed fracture sites, aggressive early wound excision debridement, early internal fixation, and vascularized wound coverage within a few days after trauma were proposed. A negative-pressure dressing can be easily and rapidly ap…
High-energy extracorporeal shock wave treatment of nonunions.
2001
Forty-three consecutive patients who did not have healing of tibial or femoral diaphyseal and metaphyseal fractures and osteotomies for at least 9 months after injury or surgery were examined prospectively for use of high-energy extracorporeal shock waves. Former treatment modalities (cast, external fixator, plate osteosynthesis, limitation of weightbearing) remained unchanged. In all cases a 99m Technetium dicarboxyphosphonate regional two-phase bone scintigraphy was performed before one treatment with 3000 impulses of an energy flux density of 0.6 mJ/mm 2 . Radiologic and clinical followups were done at 4-week intervals starting 8 weeks after shock wave treatment. The success criterion wa…
The outcomes of Ilizarov treatment in aseptic nonunions of the tibia stratified by treatment strategies and surgical techniques.
2020
Abstract INTRODUCTIONNonunions of the tibia, particularly those located in the distal third of the bone, are relatively common in clinical practice. There is no gold standard for the treatment of nonunions of the tibia. The purpose of our study was to assess the results of treatment with the Ilizarov method in patients with aseptic nonunions of the tibia, depending on the employed treatment strategies and surgical techniques.MATERIALS AND METHODSA total of 75patients with Ilizarov treatment of aseptic nonunions of the tibia were evaluated in the study. The patients’s mean age at the beginning of treatment was 46years.The mean follow-up period was 10years and 11months.The evaluated patients …
Assessment of Lower Limb Load Distribution in Patients Treated with the Ilizarov Method for Tibial Nonunion
2021
BACKGROUND Successful treatment of tibial nonunion should lead to a complete bone union, lack of pain, and pathological mobility of the lower extremity, as well as to the achievement of satisfactory joint mobility and muscle strength, which in turn improves its biomechanics. The objective of this study was to assess the load placed on the lower limbs in patients subjected to treatment with the Ilizarov method due to aseptic tibial nonunion. MATERIAL AND METHODS This research involved 24 participants (average age, 55 years). All were diagnosed with aseptic tibia nonunion and treated with the Ilizarov external fixator between 2000 and 2017. The control group was matched to the treated group i…
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.
1998
Abstract During 41 procedures of intramedullary nailing of femoral and tibial fractures, the primary surgeon and the first assistant wore ring dosimeters on their dominant index fingers. While the average fluoroscopy time per procedure was 4.6 min, the average dose of radiation to the dominant hand of the primary surgeon was 1.27 mSv and 1.19 mSv to the first assistant. The dose limit for the extremities is 500 mSv per year, as recommended by the International Commission on Radiological Protection. Extrapolation of the mean dose of the primary surgeon and first assistent per procedure of 1.23 mSv leads to the result that the recommended dose limit of 500 mSv would only be exceeded if more t…
Asymmetry of gait after free flap reconstruction of severe tibial fractures with extensive soft-tissue damage.
2000
Gait patterns of the preferred speed were investigated on 17 patients recovering (9 months-14 years) after reconstruction of severe tibial fractures. A novel data-acquisition system was used to record the plantar pressures as well as electromyographic (EMG) activities during walking. The results indicated incomplete recovery of symmetrical gait patterns. In particular, the duration of the stance phase was shorter on the operated side (mean (SD) 701 (90) ms compared with 765 (128) ms, p < 0.001). The peak pressure points under the foot were different on bilateral comparison, the operated side being regularly higher under the lateral forefoot area. This may imply attempts to reduce the loadin…
Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture
2021
Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…
Valoración funcional en pacientes intervenidos mediante plastia de LCA con semitendinoso-recto interno y sistema Togglelock.
2020
espanolIntroduccion: Una de las lesiones mas frecuente de la rodilla y que esta en aumento, sobre todo en el ambito deportivo es la lesion del ligamento cruzado anterior. La reconstruccion quirurgica es fundamental para recuperar la biomecanica de la rodilla, proporcionar una correcta estabilidad y funcionamiento libre de dolor, asi como evitar cambios degenerativos tempranos. El objetivo del presente estudio fue valorar la recuperacion funcional de los pacientes sometidos a una reconstruccion del ligamento cruzado anterior mediante ligamentoplastia con tendon semitendinoso-recto interno y sistema Toggelock. Material y metodos: Se diseno un estudio retrospectivo descriptivo observacional, e…
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach
2020
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…
Virtual prototyping of a new intramedullary nail for tibial fractures
2012
In this work a new distal interlocking system has been developed which is easy to use, allows a reduction of the operating time and consequently the exposure to radiations both for surgeon and patient. The main goal of this study has been the design of a new intramedullary nail for tibial fractures able to simplify and speed up the distal locking operation phases. After a preliminary stage during which several candidate concepts have been proposed and analysed, the best solution has been developed and deeply investigated. The new system, called “expansion nail”, has been firstly modelled by setting up a full parametric CAD model and, then, tested by running non linear FEM analyses to evalua…